Industry’s Lowest-Power
Ambient Light Sensor with ADC
Interrupt events set the INTS bit (register 0x00, bit 0) and the INT pin only if the INTE bit is set to 1. If the INTE bit is set
(interrupt is enabled) and the interrupt condition is triggered, then the INT pin is pulled low (asserted) and the INTS bit
in the Interrupt Status register is set to 1. See Table 3.
Table 3. Interrupt Enable Register
BIT 0
0
1
OPERATION
The INT pin and the INTS bit are not asserted even if an interrupt event has occurred.
Detection of an interrupt event triggers a hardware interrupt ( INT pin is pulled low) and sets the INTS bit
(register 0x00, bit 0).
Configuration 0x02
BIT 7
CONT
BIT 6
MANUAL
BIT 5
BIT 4
BIT 3
CDR
BIT 2
BIT 1
TIM[2:0]
BIT 0
REGISTER
ADDRESS
0x02
Continuous Mode
Table 4. Continuous Mode Register
BIT 7
0
1
OPERATION
Default mode. The IC measures lux intensity only once every 800ms regardless of integration time. This
mode allows the part to operate at its lowest possible supply current.
Continuous mode. The IC continuously measures lux intensity. That is, as soon as one reading is finished, a
new one begins. If integration time is 6.25ms, readings are taken every 6.25ms. If integration time is 800ms,
readings are taken every 800ms. In this mode, the part consumes slightly higher power than in the default
mode.
Note: Continuous mode is independent of the manual configuration mode setting.
Manual Configuration Mode
In automatic mode (MANUAL = 0), reading the contents of TIM[2:0] and CDR bits reflects the automatically generated
values from an internal timing register and are read-only. In manual mode (MANUAL = 1), the contents of TIM[2:0] and
CDR bits can be modified by the users through the I 2 C bus.
Table 5. Manual Configuration Register
BIT 6
0
1
OPERATION
Default mode of configuration is used for the IC. In this mode, CDR and TIM[2:0] bits are automatically deter-
mined by the internal autoranging circuitry of the IC.
Manual mode of configuration is used for the IC. In this mode, CDR and TIM[2:0] bits can be programmed
by the user.
Current Division Ratio (CDR)
The CDR bit controls the current division ratio. The photodiode current is divided as shown in Table 6.
Table 6. Current Division Ratio Register
8
BIT 3
0
1
OPERATION
Current not divided. All of the photodiode current goes to the ADC.
Current divided by 8. Only 1/8 of the photodiode current goes to the ADC. This mode is used in
high-brightness situations.
相关PDF资料
MAX9930EVKIT+ KIT EVAL FOR MAX9930
MAX9947ETE+ TXRX AISG INTEGRATED 16TQFN
MAX9981ETX+D IC MIXER DUAL SIGE 36-QFN
MAX9981EVKIT EVAL KIT FOR MAX9981
MAX9982ETP+D IC MIXER HI LINEAR SIGE 20-TQFN
MAX9982EVKIT EVAL KIT FOR MAX9982
MAX9984ETP+T IC MIXER DOWN CONV 20-TQFN
MAX9985ETX+T IC MIXER DOWN CONV DUAL 36-TQFN
相关代理商/技术参数
MAX9635ESA+T 功能描述:环境光传感器 Ambient Light Sensor RoHS:否 制造商:Vishay Semiconductors 工作电源电压: 峰值波长:570 nm 最大工作温度:+ 85 C 最小工作温度:- 40 C 封装 / 箱体:T-1 封装:Bulk
MAX9635EVKIT 功能描述:光学传感器开发工具 MAX9635 Eval Kit RoHS:否 制造商:ams 工具用于评估: 接口类型: 最大工作温度:
MAX9635EVKIT# 功能描述:环境光传感器 Industry’s Lowest-Power Ambient Light Sensor with ADC RoHS:否 制造商:Vishay Semiconductors 工作电源电压: 峰值波长:570 nm 最大工作温度:+ 85 C 最小工作温度:- 40 C 封装 / 箱体:T-1 封装:Bulk
MAX9635EVKIT+ 功能描述:光学传感器开发工具 MAX9635 Eval Kit RoHS:否 制造商:ams 工具用于评估: 接口类型: 最大工作温度:
MAX9636AXT+ 制造商:Maxim Integrated Products 功能描述: 制造商:Maxim Integrated Products 功能描述:3V/5V LOW-POWER LOW-NOISE RAIL-TO-RAIL I/O OP AMP (SINGLE CH - Rail/Tube
MAX9636AXT+T 功能描述:运算放大器 - 运放 3V-5V Low-Power Op Amp RoHS:否 制造商:STMicroelectronics 通道数量:4 共模抑制比(最小值):63 dB 输入补偿电压:1 mV 输入偏流(最大值):10 pA 工作电源电压:2.7 V to 5.5 V 安装风格:SMD/SMT 封装 / 箱体:QFN-16 转换速度:0.89 V/us 关闭:No 输出电流:55 mA 最大工作温度:+ 125 C 封装:Reel
MAX9636EVKIT+ 功能描述:放大器 IC 开发工具 MAX9636 Eval Kit RoHS:否 制造商:International Rectifier 产品:Demonstration Boards 类型:Power Amplifiers 工具用于评估:IR4302 工作电源电压:13 V to 23 V
MAX9637AXA+ 制造商:Maxim Integrated Products 功能描述:OPERATIONAL AMPLIFIER - Rail/Tube